FD-HCN-SENSOR – Hydrogen Cyanide Sensor (HCN) | 0 – 50 ppm

Price:

Model: FD-HCN-SENSOR
Datasheet: Click Here PDF
Availability: Usually in stock
Compatible: FD-90A-HCN

Features

  • ⚛️ High precision and long life (2 years)
  • 🚄 Fast response speed, fast return to zero
  • 🔋 Low power consumption, high sensitivity
  • 🔬Wide linear range, strong anti-interference ability
  • 💪 Excellent repeatability and stability

Description

These are generic HCN sensors used as the pin-to-pin replacement of the standard 4-series electrochemical sensors. It is used throughout many gas detector brands and is an excellent HCN gas sensor replacement element.

Our HCN sensor employs an advanced electrolytic mechanism where hydrogen cyanide and oxygen interact through precise redox reactions on specialized electrodes. By generating an electrical current directly proportional to the gas concentration, this sophisticated sensor enables accurate measurement of hydrogen cyanide levels. The current’s magnitude provides a quantitative assessment of HCN presence in various industrial and environmental monitoring applications.

Hydrogen cyanide detection technologies play a critical role across diverse industrial and municipal domains. From manufacturing facilities and maritime operations to power generation and municipal infrastructure, HCN detectors provide comprehensive gas concentration insights. These advanced sensing systems enable precise measurement, early warning mechanisms, and critical monitoring, supporting safety, environmental protection, and risk mitigation in multiple application sectors.

Instructions

  • Once replaced and installed in your gas detector or analyzer, please let it sit for 24 hours so the sensor can stabilize to your environment. This step is very important.
  • Then undertake the appropriate zero and calibration for your specific gas detector. See your gas detector manufacturer’s specific instructions.
  • Once calibrated, your gas analyzer will be ready for use.

Specifications

Detection PrincipleElectrochemical Three electrodes
Detection GasHCN
Detection Range0-50 PPM
Maximum Load Concentration100 PPM
Output Signal100±30 nA/PPM
Zero Drift-1~1 PPM
Resolution0.1 PPM
Response Time≤120s
Bias Voltage0
Load Resistance5~30Ω
Working Temperature-30℃-50℃
Working Humidity15%RH to 90%RH (no condensation)
Repeatability<±2% output signal
Long-term Stability<2% signal/month
LinearityRegression coefficient R²=0.999
Work Pressure90 to 110 kPa
Shelf Life12 months after delivery
Service Life2 years

Cross-Sensitivity Data

Interfering GasGas Concentration Used (ppm)Value Displayed (ppm HCN)
CO1000
H2S2652
CL216.30
NO180
NO223-1
SO2238